Pagina 1 - SPARC Enterprise

Dynamic Reconfiguration (DR) User’s GuideSPARC Enterprise M4000 / M5000 / M8000 / M9000 Servers English

Pagina 2

viii SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 20074.5 Examples: Replacing a System Board 4–124.5.1 Example: Rep

Pagina 3 - (DR) User's Guide

4-10 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 20074.4 Example: Moving a System BoardThis section provides an ex

Pagina 4

Chapter 4 Practical Examples of DR 4-113. Check the status of the move-destination domain.Execute the showdcl(8) command to display domain information

Pagina 5

4-12 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 20077. Check the status of the move-destination domain and moved

Pagina 6

Chapter 4 Practical Examples of DR 4-134.5.1 Example: Replacing a Uni-XSB System BoardFIGURE 4-8 Example: Replacing a Uni-XSB System Board1. Login to

Pagina 7 - Contents

4-14 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 20074. Delete the system board.Execute the deleteboard(8) command

Pagina 8

Chapter 4 Practical Examples of DR 4-158. Check the status of the domain.Execute the showdcl(8) command to display domain information, and thencheck t

Pagina 9 - Contents vii

4-16 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 20074.5.2 Example: Replacing a Quad-XSB System BoardFIGURE 4-9 Ex

Pagina 10

Chapter 4 Practical Examples of DR 4-173. Check the status of all related system boards.Execute the showboards(8) command to display system board info

Pagina 11

4-18 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 20076. Check the status of all related system boards.Execute the

Pagina 12

Chapter 4 Practical Examples of DR 4-199. Check the status of all related domains.Execute the showdcl(8) command to display domain information, and th

Pagina 13

ixFiguresFIGURE 1-1 Uni-XSB and Quad-XSB (Midrange Servers) 1–2FIGURE 1-2 Uni-XSB and Quad-XSB (High-end Servers 1–3FIGURE 1-3 DR Processing Flow 1–5F

Pagina 14 - DR-related Commands 3–26

4-20 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 20074.6 Examples: Reserving DomainConfiguration ChangesThis secti

Pagina 15 - Preface xiii

Chapter 4 Practical Examples of DR 4-212. Check the status of the system board to be added.Execute the showboards(8) command to display system board i

Pagina 16 - Audience

4-22 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 20074.6.2 Example: Reserving a System Board DeleteFIGURE 4-11 Exa

Pagina 17 - Documentation

Chapter 4 Practical Examples of DR 4-235. Check the reserved status of the system board.Execute the showboards(8) command with the -v option specified

Pagina 18 - Book Titles Order No

4-24 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 20073. Check the status of the move-destination domain.Execute th

Pagina 19 - Documents

Chapter 4 Practical Examples of DR 4-258. Check the status of the move-destination domain and moved system board.Execute the showdcl(8) command to che

Pagina 20 - Text Conventions

4-26 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007

Pagina 21 - Prompt Notations

A-1APPENDIXAMessage Meaning and HandlingThis appendix explains the meaning and handling of DR-related messages.A.1 Solaris OS MessagesThis section exp

Pagina 22 - Your Comments

A-2 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007OS unconfigure dr@0:SBX::memory[Explanation] Unconfigure memor

Pagina 23 - Reader's Comment Form

Appendix A Message Meaning and Handling A-3[Explanation] Suspending device driversDR: in-kernel unprobe board <board>[Explanation] Unprobing the

Pagina 24 - BUSINESS REPLY MAIL

x SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007FIGURE 4-10 Example: Reserve a System Board Add 4–20FIGURE 4-11

Pagina 25 - Reconfiguration

A-4 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007[Explanation] Internal error during kernel migration[Remedy] P

Pagina 26 - Quad-XSB

Appendix A Message Meaning and Handling A-5[Remedy] Disable interrupt on cpu X with psradm -I and if this command failsagain, respond in the manner di

Pagina 27

A-6 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007[Explanation] There may be inconsistency in the system.[Remedy

Pagina 28 - Basic DR Terms

Appendix A Message Meaning and Handling A-7dr_pre_release_cpu: thread(s) bound to cpu X[Explanation] The thread in the process is bound to the detache

Pagina 29 - 1.2 Basic DR Functions

A-8 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007[Remedy] Please repeat the action. If the problem remains, ple

Pagina 30 - 1.2.3 Moving a System Board

Appendix A Message Meaning and Handling A-9Cannot stop user thread: <pid> <pid> ...[Explanation] The DR driver cannot stop all the user pr

Pagina 31 - 1.3 Security

A-10 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007Invalid argument[Explanation] Invalid argument is passed to t

Pagina 32

Appendix A Message Meaning and Handling A-11[Explanation] There may be inconsistency in the system.[Remedy] Please contact customer service.[Output] C

Pagina 33 - 2.1.1 System Board Components

A-12 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007[Explanation] DR fails to allocate enough memory to perform c

Pagina 34

Appendix A Message Meaning and Handling A-13[Explanation] Detected lack of memory resource.[Remedy] Check the size of memory, detach the board and att

Pagina 35

xiTablesTABLE 1-1 Basic DR Terms 1–3TABLE 1-2 Terms Related to Hardware Configurations 1–4TABLE 2-1 Unit of Degradation 2–14TABLE 2-2 Domain Status 2–

Pagina 36 - 2.1.1.1 CPU

A-14 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007Memory operation refused: dr@0:SBX::memory[Explanation] The D

Pagina 37 - (1) Kernel Memory Board

Appendix A Message Meaning and Handling A-15[Remedy] Repeat the action. If this error message appears again, please contactcustomer service.[Output] C

Pagina 38 - (1.2) Floating Boards

A-16 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007Operation already in progress: dr@0:SBX::cpuY[Explanation] Th

Pagina 39 - (1.4) Copy-rename

Appendix A Message Meaning and Handling A-17[Output] Console and Standard OutputCannot setup resource map opl-fcodemem[Explanation] Resource memory ma

Pagina 40 - (2) User Memory Board

A-18 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007[Explanation] A claim request with a nonzero hint came from t

Pagina 41 - (2) Deleting an I/O Device

Appendix A Message Meaning and Handling A-19[Explanation] The node was not destroyed.[Remedy] Please contact customer service.IKP: destroy chip (<b

Pagina 42

A-20 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007[Remedy] Please contact customer service.I/O callback failed

Pagina 43

Appendix A Message Meaning and Handling A-21[Remedy] Please contact customer service.Failed to remove CMP xx on board n[Explanation] Internal error du

Pagina 44 - 2.2.1 Conditions Using XSCF

A-22 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007[Explanation] An unknown resource type was found in the resou

Pagina 45 - 2.2.2 Settings Using XSCF

Appendix A Message Meaning and Handling A-23SCF error[Explanation] Internal error happened during kernel migration.[Remedy] Please contact customer se

Pagina 46 - 2.2.2.2 Floating Board Option

xii SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007TABLE 3-15 Options of the moveboard Command 3–20TABLE 3-16 DR

Pagina 47 - 2.2.2.4 Omit-I/O Option

A-24 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007XSB#XX-X is currently unavailable for DR. Try again later.[Ex

Pagina 48

Appendix A Message Meaning and Handling A-25[Remedy] Find out the cause of the DR failure referring monitoring message anderrorlog. Confirm the patch

Pagina 49 - 2.4.1 Domain Status

A-26 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007An internal error has occurred. Please contact your systemadm

Pagina 50 - 2.4.2 System Board Status

Appendix A Message Meaning and Handling A-27[Explanation] The specified system board (XSB#XX-X) has already been executedby another operation.[Remedy]

Pagina 51 - System Board Management Items

A-28 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007Invalid parameter.[Explanation] There is an error in the spec

Pagina 52 - 2.4.3 Flow of DR Processing

Appendix A Message Meaning and Handling A-29[Explanation] Confirming whether DR operation is going to be executed or not.Input "y" to execut

Pagina 53

A-30 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007[Remedy] Power off the domain by specifying "-c reserve&

Pagina 54

Appendix A Message Meaning and Handling A-31[Remedy] Find out the cause of the DR failure referring monitoring message andconsole message. Try again a

Pagina 55

A-32 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007[Explanation] Confirming whether DR operation is going to be

Pagina 56

Appendix A Message Meaning and Handling A-33Invalid parameter.[Explanation] There is an error in the specified argument or operand.[Remedy] Confirm th

Pagina 57

Preface xiiiPrefaceThis manual describes the Dynamic Reconfiguration (DR hereafter) functionprovided by SPARC Enterprise servers.This manual is intend

Pagina 58

A-34 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007The specified parameter is not supported in this model.[Expla

Pagina 59 - 2.5.2 Swap Area

Appendix A Message Meaning and Handling A-35[Remedy] Confirm that the DSCP setting is correct, confirm that the dsc process isrunning fine on the doma

Pagina 60 - 2.5.4 Memory Mirror Mode

A-36 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007

Pagina 61 - 2.5.6 XSCF Failover

B-1APPENDIXBExample: Confirm Swap Space SizeThis example shows one way to analyze the physical memory on a system board todetermine whether the system

Pagina 62

B-2 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007Notice in the Memory section that 2048 MB (2GB) of physical me

Pagina 63 - DR User Interface

Glossary-1GlossaryThis glossary describes some of the terms used in this manual.Capacity on Demand(COD) An option that provides additional CPU process

Pagina 64 - DR Operation Commands

Glossary-2 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007eXtended SystemControl facility unit(XSCFU) The XSCF bo

Pagina 65 - Display items Description

Glossary-3privileges Specific permissions granted to users. This system has platform administrator,platform operator, domain administrator, domain ope

Pagina 66

Glossary-4 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007

Pagina 67

Index-1IndexAAdd, 1-3addboard, 3-2, 3-15, 3-22addfru, 3-26addition, 1-6, 2-20, 2-27, 3-15, 4-2, 4-6Assign, 1-3BBasic DR Terms, 1-3CCapacity on Demand,

Pagina 68

xiv SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007AudienceThis manual is intended for users, who administrate SP

Pagina 69

Index-2 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007move, 1-6, 2-23, 3-19, 4-4, 4-10moveboard, 3-2, 3-19Oomit-I

Pagina 71

Herausgegeben von / Published byFujitsu Siemens Computers GmbH*U41684-J-Z816-2-76 *U41684-J-Z816-2-76 Bestell-Nr./ Order No.:U41684-J-Z816-2-76

Pagina 72

Preface xvGlossary and Index GlossaryThe glossary explains the terms used in this manual IndexThe index provides keywords and corresponding referenc

Pagina 73

xvi SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007Note – " x " in the order number is the version numb

Pagina 74

Preface xviiContact the field engineer.The following files or document are provided.i. Firmware program file (XSCF Control Package (XCP) file)ii. XSCF

Pagina 76

xviii SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007ModelsThe model names used in this manual are as follows.Tex

Pagina 77 - 3.1.6 Adding a System Board

Preface xixPrompt NotationsThe prompt notations used in this manual are as follows.Syntax of the Command Line Interface(CLI)The command syntax is desc

Pagina 78

xx SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007 The command syntax is shown in a frame such as this one.Examp

Pagina 79 - 3.1.7 Deleting a System Board

Preface xxiReader's Comment Form

Pagina 80

xxii SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007FOLD AND TAPEFOLD AND TAPEBUSINESS REPLY MAILFIRST-CLASS MAIL

Pagina 81 - 3.1.8 Moving a System Board

1-1CHAPTER1Overview of DynamicReconfigurationThis chapter provides an overview of Dynamic Reconfiguration, which is controlledby the eXtended System C

Pagina 82

1-2 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007into four boards is called a Quad-XSB. Each composition of phy

Pagina 83

Chapter 1 Overview of Dynamic Reconfiguration 1-3FIGURE 1-2 Uni-XSB and Quad-XSB (High-end ServersTABLE 1-1 and TABLE 1-2 list DR-related terms.TABLE

Pagina 84

1-4 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007Unconfigure To unconfigure a system board in the Solaris OS.Re

Pagina 85

Chapter 1 Overview of Dynamic Reconfiguration 1-51.2 Basic DR FunctionsThis section describes the basic DR functions.FIGURE 1-3 shows DR processing.FI

Pagina 86

SPARC®EnterpriseM4000/M5000/M8000/M9000Servers Dynamic Reconfiguration(DR) User's GuideOrder No. U41684-J-Z816-2-76Part No.819-7898-11September 20

Pagina 87 - 3.2 Command Reference

1-6 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007In the example shown in FIGURE 1-3, system board #2 is deleted

Pagina 88 - DR-related Commands

Chapter 1 Overview of Dynamic Reconfiguration 1-71.2.4 Replacing a System BoardYou can use DR to remove a system board from a domain and either add it

Pagina 89 - 3.4 RCM Script

1-8 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007For details of XSCF shell commands provided for DR, see Sectio

Pagina 90

2-1CHAPTER2What You Must Know Before UsingDRThis chapter provides information you must know to successfully use the DRfunctions.2.1 System Configurati

Pagina 91 - Practical Examples of DR

2-2 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007FIGURE 2-1 Example of Hardware Configuration (with Uni-XSB of

Pagina 92

Chapter 2 What You Must Know Before Using DR 2-3FIGURE 2-2 Example of Hardware Configuration (with Quad-XSBs of Midrange Server)CMU IOUMemoryXSB 00-2M

Pagina 93

2-4 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007FIGURE 2-3 Example of a Hardware Configuration (with Uni-XSBs

Pagina 94 - - Operation status and

Chapter 2 What You Must Know Before Using DR 2-5A CPU to be deleted must meet the following conditions: No running process is bound to the CPU to be

Pagina 95 - Addition reservation

2-6 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007 To control whether a system board contains kernel memory, us

Pagina 96

Chapter 2 What You Must Know Before Using DR 2-7When the kernel cage is enabled, kernel memory is assigned to system boards in theorder of their addre

Pagina 97

PleaseRecycleCopyright 2007 FUJITSU LIMITED, 1-1, Kamikodanaka 4-chome, Nakahara-ku, Kawasaki-shi, Kanagawa-ken 211-8588, Japan. All rightsreserved.Su

Pagina 98

2-8 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007Once the copy-destination board has been selected, the Solaris

Pagina 99

Chapter 2 What You Must Know Before Using DR 2-9Deleting or moving a user memory board fails if either of the following statements istrue: The swap a

Pagina 100 - 00 Running

2-10 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007Note – Do not move a device that is part of a redundant confi

Pagina 101

Chapter 2 What You Must Know Before Using DR 2-11Moreover, a system board that is pooled can be assigned to a domain only when it isregistered on DCL.

Pagina 102

2-12 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007When kernel memory is copied, the Solaris OS is temporarily s

Pagina 103

Chapter 2 What You Must Know Before Using DR 2-13operation.As a matter of course, system boards to be deleted, moved, or replaced have alreadybeen reg

Pagina 104

2-14 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007Note – Enable the configuration policy option when the power

Pagina 105

Chapter 2 What You Must Know Before Using DR 2-152.2.2.3 Omit-memory OptionWhen the omit-memory option is enabled, the memory on a system board cannot

Pagina 106

2-16 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007Note – Enable the omit-I/O option when the system board is in

Pagina 107

Chapter 2 What You Must Know Before Using DR 2-17If the kernel cage is disabled, the system may run more efficiently, but kernelmemory will be spread

Pagina 108

Copyright 2007 FUJITSU LIMITED, 1-1, Kamikodanaka 4-chome, Nakahara-ku, Kawasaki-shi, Kanagawa-ken 211-8588, Japon. Tous droitsréservés.Entrée et revu

Pagina 109

2-18 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007XSCF manages the following aspects of domain status:To perfor

Pagina 110 - Configuration Changes

Chapter 2 What You Must Know Before Using DR 2-19The table below lists the status types available for individual management items.XSCF changes and con

Pagina 111

2-20 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007To perform a DR operation for a system board, you must determ

Pagina 112

Chapter 2 What You Must Know Before Using DR 2-21FIGURE 2-5 Flow of System Board Addition Processing2.4.3.2 Flowchart: Deleting a System BoardThe flow

Pagina 113

2-22 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007Each system board status indicated in FIGURE 2-6 is the main

Pagina 114

Chapter 2 What You Must Know Before Using DR 2-232.4.3.3 Flowchart: Moving a System BoardThe flow of DR operations and the transition of system board

Pagina 115

2-24 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007FIGURE 2-7 Flow of System Board Move ProcessingProcess to cha

Pagina 116

Chapter 2 What You Must Know Before Using DR 2-252.4.3.4 Flowchart: Replacing System BoardThe flow of DR operations and the transition of system board

Pagina 117 - A.1.1 Transition Messages

2-26 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007FIGURE 2-8 Flow of System Board Replacement ProcessingDeletio

Pagina 118

Chapter 2 What You Must Know Before Using DR 2-272.5 Operation ManagementThis section describes the premises and the actions for DR operations.2.5.1 I

Pagina 120 - A.1.3 Warning Messages

2-28 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007memory contents. Be aware that some of the total swap space m

Pagina 121

Chapter 2 What You Must Know Before Using DR 2-29For example, when a kernel memory board with memory mirror mode enabled isdeleted or moved, kernel me

Pagina 122

2-30 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 20072.5.8 Deletion of Board with DVD DriveTo delete the system bo

Pagina 123

3-1CHAPTER3DR User InterfaceThis chapter describes the user interfaces for DR.3.1 How To Use the DR User InterfaceXSCF provides two user interfaces fo

Pagina 124

3-2 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007The sections below describe the DR display and DR operation co

Pagina 125

Chapter 3 DR User Interface 3-3TABLE 3-3 Options of the showdcl CommandOption Description-a Displays configuration information and status of all domai

Pagina 126

3-4 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007The table below lists the items displayed by the showdcl(8) co

Pagina 127

Chapter 3 DR User Interface 3-53.1.2 Displaying Domain StatusThe showdomainstatus(8) command lists the domains in the system and theirstatus. This com

Pagina 128

3-6 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007The following example shows a display of the showdomainstatus

Pagina 129

Chapter 3 DR User Interface 3-7The following examples show the format and options of the showboards(8)command.The table below lists the items displaye

Pagina 130

vContentsPreface xiii1. Overview of Dynamic Reconfiguration 1–11.1 DR 1–11.2 Basic DR Functions 1–51.2.1 Adding a System Board 1–61.2.2 Deleting a Sys

Pagina 131

3-8 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007Assignment Status of assignment to domain configurationUnavail

Pagina 132

Chapter 3 DR User Interface 3-9The following examples show displays of the showboards(8) command Example 1: Display of information on all system boar

Pagina 133

3-10 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007 Example 2: Display of detailed information on all system bo

Pagina 134

Chapter 3 DR User Interface 3-11Note – The showdevices(8) command only reports information about a runningdomain.TABLE 3-9 Options of the showdevices

Pagina 135

3-12 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007The following example shows a display by the showdevices(8) c

Pagina 136

Chapter 3 DR User Interface 3-13 Example: Display of device information on XSB00-03.1.5 Displaying System Board ConfigurationInformationUse the showf

Pagina 137

3-14 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007The table below lists the items displayed by the showfru(8) c

Pagina 138

Chapter 3 DR User Interface 3-153.1.6 Adding a System BoardUse the addboard(8) command to add a system board to a domain or reserve theaddition of a s

Pagina 139 - A.2.1 addboard

3-16 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007Note – (Note 1) In the system board addition processing execu

Pagina 140

Chapter 3 DR User Interface 3-17Note – (Note 3) If a system board has been forcibly added to a domain by theaddboard(8) command with the -f option spe

Pagina 141

vi SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 20072.1.4 Checklists for System Configuration 2–112.1.5 Reservation

Pagina 142 - A.2.2 deleteboard

3-18 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007TABLE 3-14 Options of the deleteboard CommandOption Descripti

Pagina 143

Chapter 3 DR User Interface 3-19Note – (Note 1) The time required for system board deletion processing depends onthe amount of hardware resources moun

Pagina 144 - A.2.3 moveboard

3-20 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007The following examples show the format and options of the mov

Pagina 145

Chapter 3 DR User Interface 3-21Note – (Note 1) The time required for system board deletion processing in themove-source domain depends on the amount

Pagina 146

3-22 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007Note – (Note 2) If the DR processing executed by the moveboar

Pagina 147

Chapter 3 DR User Interface 3-23Note – (Note 1) Before replacing a system board, you must know the division typeof the replacement-target PSB and the

Pagina 148 - A.2.4 setdcl

3-24 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 20073.1.10 Reserving a Domain Configuration ChangeUse the addboar

Pagina 149 - A.2.5 setupfru

Chapter 3 DR User Interface 3-253.2 Command ReferenceThis section lists the DR commands and other commands related to DR.For details of the commands,

Pagina 150 - A.2.6 showdevices

3-26 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007TABLE 3-18 DR-related CommandsCommand name Functionpoweron Tu

Pagina 151

Chapter 3 DR User Interface 3-273.3 XSCF WebXSCF Web lets you execute DR functions from a browser. XSCF Web is beyond thescope of this document. For d

Pagina 152

Contents vii2.5.6 XSCF Failover 2–292.5.7 Kernel Memory Board Deletion 2–292.5.8 Deletion of Board with DVD Drive 2–303. DR User Interface 3–13.1 How

Pagina 153

3-28 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007

Pagina 154

4-1CHAPTER4Practical Examples of DRThis chapter provides examples of DR operations, such as the addition, deletion,move, and replacement of system boa

Pagina 155 - Glossary

4-2 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 20074.1.1 Flow: Adding a System BoardFIGURE 4-1 Flow: Adding a Sys

Pagina 156

Chapter 4 Practical Examples of DR 4-34.1.2 Flow: Deleting a System BoardFIGURE 4-2 Flow: Deleting a System BoardChecking operation andChecking the do

Pagina 157

4-4 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 20074.1.3 Flow: Moving a System BoardFIGURE 4-3 Flow: Moving a Sys

Pagina 158

Chapter 4 Practical Examples of DR 4-54.1.4 Flow: Replacing a System BoardFIGURE 4-4 Flow: Replacing a System BoardDeletion reservationoperation for t

Pagina 159

4-6 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 20074.2 Example: Adding a System BoardThis section provides an exa

Pagina 160

Chapter 4 Practical Examples of DR 4-7If you need to change the PSB configuration, use the setupfru(8) command. Ifthe system board to be added is not

Pagina 161

4-8 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 20074.3 Example: Deleting a System BoardThis section provides an e

Pagina 162 - *U41684-J-Z816-2-76 *

Chapter 4 Practical Examples of DR 4-93. Check the status of the system board to be deleted.Execute the showboards(8) command to display system board